<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-19 14-04-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.90 MHz 4/5, 54 dBuV RTL2
Pilot RDS Phase Difference
6.8 kHz 3.8 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 75 kHz 10020 29,4511
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
8,3 dBr 8,57 dBr 8,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 14:04, 19.01.2025
RT
"RTL2, Le Son POP-ROCK "
AF EON
88.2, 89.1, 89.2, 90.1, 92.2, 92.4, 94.4, 95.9, 96.6, 97.3, 97.4, 98.0, 98.2, 98.3, 98.9, 99.3, 101.3, 103.2, 105.1, 105.3, 105.9, 106.0, 106.1, 106.9 MHz -
FM Scope Station: 105.90 MHz, signal: 5/5 (55 dBuV) Max at: 75 kHz MIN: 12 kHz % above 75 kHz: 29,4511 Acquired: 2025/01/19 14:03:01 Total samples: 10020 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,8 dBr MIN: 8,3 dBr AVE: 8,57 dBr % above 10,0 dBr: 0,0 Last value: 8,4 dBr (2025/01/19 14:03:00) Station: 105.90 MHz, signal: 5/5 (55 dBuV) 13:56 13:57 13:58 13:59 14:00 14:01 14:02 14:03 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality